米兰官网AC Milan

        Preparation of acid-washed glass coverslips for immunofluorescence microscopy

        Jenna Ekstrom

        Published: 2024-05-17 DOI: 10.17504/protocols.io.6qpvr847blmk/v1
        AI 解读
        浏览 1434

        Abstract

        Rizzardi Lab (Adapted from Schwer Lab- UCSF)

        Steps

        1.

        Add coverslips to 10cm culture dish

        2.

        Add ~20 mL of 1 N HCl; swirl on orbital shaker for 2 h at RT.Room temperature

        3.

        Remove acid, rinse with 2 x 25 mL PBS until pH is at least 6.0.

        4.

        Rinse 1 x 25 mL water.

        5.

        Add ~20 mL of 70% EtOH; swirl on orbital shaker for 10 min, RT.Room temperature

        6.

        Remove ethanol, transfer coverslips to Whatman paper. Let dry in TC hood.

        7.

        Sterilize coverslips before use

        7.1.

        Option 1:

        Transfer to glass beaker, cover with aluminum foil and autoclave (dry cycle, 30 min sterilization time)

        7.2.

        Option 2:

        Transfer to new sterile 10cm culture dish and turn on UV.  Leave in hood until ready for use.